ENDRESS HAUSER PRESSURE TRANSMITTERS
انواع ترانسمیترهای فشار کمپانی اندرس + هاوزر
Electronic differential pressure system utilizing two ceramic sensor modules and one transmitter
-
Reference accuracy up to 0.05%, long-term stability up to 0.1% / 10 year for each sensor
-
Suitable for explosion proof areas
-
Process temperature: –40 up to +150°C (–40 to +302°F), Measuring range: 400mbar to +40bar (6 to 600psi)
More information >>>
Electronic differential pressure system utilizing two metal sensor modules and one transmitter
-
Reference accuracy up to 0.05%, long-term stability up to 0.1% / 10 year for each sensor
-
Suitable for explosion proof areas
-
Process temperatures: –40 to +125°C (–40 to +257°F), Measuring range: 400mbar to +40bar (6 to 600psi)
More information >>>
Digital pressure transmitter with oil-free ceramic sensor for measurement in gases or liquids
-
Reference accuracy up to 0.075%, long-term stability up to 0.4% / 10 years
-
Membrane breakage detection, suitable for SIL2 applications
-
Process temperature: -40 to +130°C (-40 to +266°F), 150°C (302°F) for 1h, Pressure: 0/-1 to 40bar (-15/0 to +600psi) absolute/gauge
More information >>>
Digital pressure transmitter with oil-free ceramic sensor for measurement in gases or liquids
-
Reference accuracy up to 0.025%, long-term stability up to 0.2% / 10 years
-
Membrane breakage detection, suitable for SIL2/SIL3 applications
-
Process temperature: -40 to +150°C (-40 to +302°F) , Measuring ranges: 0/-1 bar up to 40bar (+1.5 to +600psi)
More information >>>
Differential pressure transmitter with metal sensor for measurement of pressure differences
-
Reference accuracy up to 0.075%, long-term stability up to 0.13% URL / 5 years
-
Suitabale for SIL2 applications
-
Temperature: -40 to 85°C (-40 to 185°F), Measuring ranges: 0.5mbar to 40bar (0.0072 to 600psi)
More information >>>
Differential pressure transmitter with metal sensor for measurement of pressure differences
-
Reference accuracy up to 0.035%, long-term stability up to 0.1% URL / 10 years
-
Suitable for SIL2/SIL3 applications
-
Temperature: -20 to 85°C (-4 to 185°F), Measuring ranges: 0.25mbar to 40bar (0.0036 to 600psi)
More information >>>
Digital pressure transmitter with welded metal sensor for measurement in gases, steam or liquids
-
Reference accuracy up to 0.075%, long-term stability up to 0.25% / 10 years
-
Suitable for SIL2 applications
-
Process temperature: -40 to +130°C (-40 to +266°F), 150°C (302°F) for 1h, Measuring range: -1/0 up to +400bar (-15/0 up to +6,000psi)
More information >>>
Digital pressure transmitter with fully welded diaphragm seal for measurement in gases or liquids
-
Reference accuracy up to 0.075%, long-term stability up to 0.25% / 10 years
-
Suitable for SIL2 applications
-
Process temperature: -70 to +400°C (-94 to +752°F), Measuring ranges: -1/0 up to +400bar (-15/0 up to +6,000psi)
More information >>>
Digital pressure transmitter with welded metal sensor for measurement in gases, steam or liquids
-
Reference accuracy up to 0.025%, long-term stability up to 0.1% / 10 years
-
Suitable for SIL2/SIL3 and custody transfer applications
-
Process temperature: -40 to +125°C (-40 to +257°F), Measuring ranges: Up to 700bar (10,500psi) absolute/gauge
More information >>>

Digital pressure transmitter with fully welded diaphragm seal for measurement in gases or liquids
-
Reference accuracy < 0.075%, long-term stability up to 0.1% / 10 years
-
Suitabale for SIL2/SIL3 appplications
-
Process temperature: -70 to +400°C (-94 to +752°F), Pressure: -1/0 up to 400bar (-15/0 up to +6,000psi)
-
More information >>>
Compact pressure sensor with the Contite measuring cell for hydrostatic level measurement
- Reference accuracy up to 0.1%, long-term stability up to 0.125% / 5 years
- Highest reliability with condensation tight Contite cell
- Process temperature: -10 to +100°C (14 to 212°F) (135°C (275°F) for 30 minutes maximum), Measuring range: 0.1 to 10bar (1.5 to 150psi)
More information >>>
Pressure sensor with the Contite measuring cell for hydrostatic level measurement
-
Reference accuracy up to 0.1%, long-term stability up to 0.125% / 5 years
-
Highest reliability with condensation tight Contite cell
-
Temperature: -10 to +85°C (14 to 185°F), Measuring range: 0.1 to 10bar (1.5 to 150psi)
More information >>>
Pressure sensor with Contite measuring cell for hydrostatic level measurement
-
Reference accuracy up to 0.1%, long-term stability up to 0.125% / 5 years
-
Highest reliability with condensation tight Contite cell
-
Temperature: With PE cable: -10 to +70°C (14 to 158°F), with FEP cable: -10 to +80°C (14 to 176°F), Measuring range: 0.1 to 10bar (1.5 to 150psi)
More information >>>
Pressure sensor with Contite measuring cell for hydrostatic level measurement
-
Reference accuracy up to 0.1%, long-term stability up to 0.125% / 5 years
-
Highest reliability with condensation tight Contite cell
-
Temperature: With PE cable: -10 to +70°C (14 to 158°F), with FEP cable: -10 to +80°C (14 to 176°F), Measuring range: 0.1 to 10bar (1.5 to 150psi)
More information >>>
Highest performance pressure sensor with the Contite cell for hydrostatic level measurement
-
Reference accuracy up to 0.075%, long-term stability up to 0.125% / 5 years
-
Highest reliability with condensation tight Contite cell
-
Temperature: -10 to +100°C (14 to 212°F) (135°C (275°F) for 30 minutes maximum), Measuring range: 0.1 to 10bar (1.5 to 150psi)
More information >>>
Differential pressure transmitter with one diaphragm seal for level measurement
-
Reference accuracy up to 0.075%, long-term stability up to 0,1% URL / 10 years
-
Suitable for SIL2/SIL3 applications
-
Temperature: -70 to +400°C (-94 to +752°F), Measuring ranges: 100mbar to +16bar (1.5 to 240psi)
More information >>>
Differential pressure transmitter with two diaphragm seals for differential pressure and level
-
Reference accuracy up to 0.075%, long-term stability up to 0.1% URL / 10 years
-
Suitable for SIL2/SIL3 applications
-
Temperature: –70 to +400°C (–94 to +752°F), Measuring range: 100mbar to 40bar (1.5 to 600psi)
More information >>>
Cost-effective pressure switch with welded metal sensor for measurement in gases, steam or liquids
-
Reference accuracy < 0.5%, long-term stability up to 0.15% URL / year
-
Function check and information on site thanks to LEDs and digital display
-
Process temperature: -40 to +100°C, Pressure: up to +400bar absolute/gauge
More information >>>
Reliable and robust level probe with ceramic measuring cell
-
Reference accuracy up to 0.2%, long-term stability up to 0.1% / 5 years
-
Robust ceramic sensor
-
Temperature: -10 to +70°C (14 to 158°F), Measuring range: 0 to 20bar (0 to 300psi))
More information >>>

Reliable and robust level probe with ceramic measuring cell and HART
-
Reference accuracy up to 0.1%, long-term stability up to 0.25% / 5 years
-
Robust ceramic sensor, density compensated level measurement
-
Temperature: -10 to +70°C (14 to 158°F), Measuring range: 0 to 20bar (0 to 300psi)
-
More information >>>
Cost-effective pressure transducer with oil-free ceramic sensor for measurement in gases or liquids
-
Reference accuracy < 0.5%, long-term stability up to 0.15% URL / year
-
Suitable for O2 applications
-
Process temperature: -20 to +100°C, Pressure: 0/-1 mbar to +40 bar absolute/gauge
More information >>>
Cost-effective pressure transducer with metal sensor for measurement in gases, steam or liquids
-
Reference accuracy < 0.5%, long-term stability up to 0.15% URL / year
-
Extremely stable, overload-resistant and reliable pressure measurement up to 400 bar
-
Process temperature: -25 to +70°C, Pressure: up to 400bar absolute/gauge
More information >>>
Cost-effective pressure transducer with fully welded metal sensor for use in hygienic applications
-
Reference accuracy < 0.5%, long-term stability up to 0.15% URL / year
-
Extremely stable, overload-resistant and reliable pressure measurement
-
Process temperature: -25 to +100°C, 135°C for 1h, Pressure: up to +40bar absolute/gauge
More information >>>
Cost-effective pressure switch with oil-free ceramic sensor for measurement in gases or liquids
-
Reference accuracy < 0.5%, long-term stability up to 0.15% URL / year
-
Membrane breakage detection and function check and information on site thanks to LEDs and digital display
-
Process temperature: -40 to +100°C, Pressure: 0/-1 up to 40bar absolute/gauge
More information >>>
Cost-effective pressure switch with fully welded metal sensor for use in hygienic applications
-
Reference accuracy < 0.5%, long-term stability up to 0.15% URL / year
-
Function check and information on site thanks to LEDs and digital display
-
Process temperature: -40 to +100°C (135°C for 1h), Pressure: up to +40bar absolute/gauge
More information >>>
Orifice: special designs for differential pressure flowmeter system based on international standards
-
Universal differential pressure flowmeter systems with primary elements and Deltabar differential pressure transmitter. Pressure reduction with restriction orifices
-
Medium temperatures: -200 to +1,000°C (-328 to +1,832°F), Pressure up to 420bar (6,300psi)
-
Pipe diameters from DN10 (3/8") to DN2000 (80")
More information >>>
Restriction orifice for creating a pressure drop upstream of a system
-
Universal differential pressure flowmeter systems with primary elements and Deltabar differential pressure transmitter. Pressure reduction with restriction orifices
-
Medium temperatures: -200 to +1,000°C (-328 to +1,832°F), Pressure up to 420bar (6,300psi)
-
Pipe diameters from DN10 (3/8") to DN2000 (80")
More information >>>